Produse>Generatoare>Uz Industrial>GBA 7

Main features

Standby power LTP :5 kW
Rated prime power (PRP) :5 kW
Rated continuous power (COP) :kW
Phases :3
Voltage :400 V
Frequency :50 Hz
Engine manufacturer :Lombardini
Fuel :Diesel
Speed governor :Mechanical

GBA Series

Seria contine generatoare de curent de baza, oferind maximum de incredere folosind componente de cea mai buna calitate.

GENERATOR * PRAMAC GBA 7

Generator (Generator ilustrativ)


  • Specificatii Tehnice
  • Echipament Standard, optiuni si accesorii

Main specifications

Type Openset
Standby power LTP 7 kVA
Standby power LTP 5 kW
Rated prime power (PRP) 6 kVA
Rated prime power (PRP) 5 kW
Rated continuous power (COP) n.a.
Rated continuous power (COP) n.a.
Phases 3
Voltage 400 V
Frequency 50 Hz
Battery charger current 55 A
Circuit breaker 10
Ratio 0,97

Engine specifications

Engine manufacturer Lombardini
Model 4LD 820
Stroke 4, diesel
Fuel Diesel
Number of cylinders and disposition 1, vertical
Displacement 817 cm³
Air intake Natural
Starting system Electric
Nominal operating speed 1500 rpm
Speed governor Mechanical
SAE n.a.
Flywheel n.a.
Continuous power COP n.a.
Prime power PRP 6 kW
Standby power LTP 6,7 kW
Lube oil capacity 2,6 l
Coolant capacity n.a.
Fuel consumption at 100% PRP 2 l/h
Fuel consumption at 75% PRP 2 l/h
Maximum lube oil consumption at PRP 0,03 %
Electric circuit voltage 12 V
Engine derating 1,0
Cooling fan Mechanical

Alternator specifications

Alternator manufacturer Linz
Model E1S13 S/4/7,5
Poles 4
Revolution speed 1500 rpm
Voltage 400 V
Frequency 50 Hz
Continuous nominal power at 40°C - COP 7 kVA
Continuous nominal power at 27°C - PRP 7 kVA
Standby power at 27 °C - LTP 7,4 kVA
Continuous active power at 27°C - PRP 6 kW
Efficiency at 75% load 81,3 %
Efficiency at 100% load 81 %
Maximum admitted overload 10% for 1 hour every 12 hours of running time S2
Voltage regulation system Compound
Alternator derating 1,0
Protection grade IP 21

Additional information

Fuel tank location Internal
Fuel tank capacity 7,2 l
Running time at 100% PRP 3,5 h
Running time at 75% PRP 5 h
Measured acoustic power (LWA) at 10 mt n.a.
Noise level at 7 m -25 dBA
Guaranteed noise level (LWA) n.a.

Dimensional data

Length 1226 mm
Width 700 mm
Height 1132 mm
Dry weight 232 kg

Equipments

Mechanical speed governor Optional
Electronic speed governor Optional
Radio interference suppression Optional
Standard AVR (Automatic Voltage Regulator) Optional
Optional AVR (Automatic Voltage Regulator) Optional
Underspeed protection Optional
12 V electric circuit Optional
24 V electric circuit Optional
Air intake filter Optional

Equipment: panel

On-board ACP (Automatic Control Panel) Optional
ACP (Automatic Control Panel), delivered loose Optional
On-board LTS (Load Transfer Switch) panel Optional
LTS (Load Transfer Switch) panel, delivered loose Optional
Power section with circuit breaker delivered loose Optional
Power section with on-board circuit breaker Optional
Differential protection Optional
Engine coolant preheater Optional
Manual oil draining pump Optional

Equipment: basic engine configuration

Optimized fuel consumption Optional

Equipment: starting system

Single pneumatic starter motor Optional
Electric starter and compressed air starter Optional
2 electric starters with separate power supply Optional

Equipment: batteries

Batteries Optional
Battery liquid Optional
Battery disconnecting device Optional

Equipment: fuel feeding system

Air filters with contamination indicator Optional
Fuel level sensor (minimum and maximum) Optional
Fuel main filter Optional
Fuel prefilter water separator Optional
Electric valve for fuel circuit Optional

Equipment: lube oil system

Lube oil filler neck, dipstick Optional
Lube oil fine filter Optional
Lube oil cooler Optional

Equipment: exhaust line

No silencer option Optional
Catalytic silencer Optional
Spark arrester Optional
Flexible exhaust compensator Optional
Connection flanges to exhaust line Optional

Equipment: silencer

Industrial silencer -15 dB(A) Optional
Residencial silencer -35 dB(A) Optional

Equipment: engine switches and senders

Fuel minimum level switch Optional
Coolant minimum level switch Optional
Coolant temperature switch Optional
Coolant temperature sender Optional
Lube oil minimum level switch Optional
Lube oil minimum pressure switch Optional
Lube oil maximum temperature switch Optional
Lube oil temperature sender Optional
Lube oil pressure sender Optional